**** SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION ****

MSDS Name: Pumice
Catalog Numbers:
    S80151-88211
Synonyms:
    None
Company Identification:  Fisher Scientific
                        1 Reagent Lane
                        Fairlawn, NJ  07410
For information, call:  201-796-7100
Emergency Number:       201-796-7100
For CHEMTREC assistance, call: 800-424-9300
For International CHEMTREC assistance, call: 703-527-3887

         **** SECTION 2 - COMPOSITION, INFORMATION ON INGREDIENTS ****

+----------------+--------------------------------------+----------+-----------+
|      CAS#      |              Chemical Name           |    %     |  EINECS#  |
|----------------|--------------------------------------|----------|-----------|
|     1332-09-8  |Pumice                                |  100.0%  | unlisted  |
+----------------+--------------------------------------+----------+-----------+
         Hazard Symbols: None Listed.
         Risk Phrases: None Listed.

                 **** SECTION 3 - HAZARDS IDENTIFICATION ****

                              EMERGENCY OVERVIEW
Appearance:  grey.
Caution! May cause mechanical eye and skin irritation.
Target Organs: None.

Potential Health Effects
    Eye:
         Dust may cause mechanical irritation.
    Skin:
         Dust may cause mechanical irritation.
    Ingestion:
         Expected to be a low ingestion hazard.
    Inhalation:
         Low hazard for usual industrial handling.
    Chronic:
         No information found.

                   **** SECTION 4 - FIRST AID MEASURES ****

    Eyes:
         Get medical aid. Do NOT allow victim to rub or keep eyes closed.
         Gently lift eyelids and flush continuously with water.
    Skin:
         Get medical aid. Flush skin with plenty of soap and water.
    Ingestion:
         If victim is conscious and alert, give 2-4 cupfuls of milk or water.
         Get medical aid if irritation or symptoms occur.
    Inhalation:
         Remove from exposure to fresh air immediately. If not breathing,
         give artificial respiration. If breathing is difficult, give oxygen.
         Get medical aid if cough or other symptoms appear.
    Notes to Physician:
         Treat symptomatically and

                 **** SECTION 5 - FIRE FIGHTING MEASURES ****

    General Information:
         As in any fire, wear a self-contained breathing apparatus in
         pressure-demand, MSHA/NIOSH (approved or equivalent), and full
         protective gear.
    Extinguishing Media:
         Use water fog, dry chemical, carbon dioxide, or regular foam.

    Autoignition Temperature:Not available.
    Flash Point:           82 deg C ( 179.60 deg F)
    Explosion Limits, lower:Not available.
    Explosion Limits, upper:Not available.
    NFPA Rating:            Not published.

               **** SECTION 6 - ACCIDENTAL RELEASE MEASURES ****

    General Information: Use proper personal protective equipment as indicated
                         in Section 8.
    Spills/Leaks:
         Vacuum or sweep up material and place into a suitable disposal
         container.

                  **** SECTION 7 - HANDLING and STORAGE ****

    Handling:
         Use with adequate ventilation.
    Storage:
         Store in a dry area.

         **** SECTION 8 - EXPOSURE CONTROLS, PERSONAL PROTECTION ****

    Engineering Controls:
         Good general ventilation should be sufficient to control airborne
         levels.

                                Exposure Limits
+--------------------+-------------------+-------------------+-----------------+
|   Chemical Name    |        ACGIH      |       NIOSH       |OSHA - Final PELs|
|--------------------|-------------------|-------------------|-----------------|
| Pumice             |none listed        |none listed        |none listed      |
+--------------------+-------------------+-------------------+-----------------+

    OSHA Vacated PELs:
         Pumice:
            No OSHA Vacated PELs are listed for this chemical.

    Personal Protective Equipment

                Eyes:
                      Wear appropriate protective eyeglasses or chemical
                      safety goggles as described by OSHA's eye and face
                      protection regulations in 29 CFR 1910.133 or European
                      Standard EN166.
                Skin:
                      Protective garments not normally required.
            Clothing:
                      Protective garments not normally required.
         Respirators:
                      Follow the OSHA respirator regulations found in 29CFR
                      1910.134 or European Standard EN 149. Always use a
                      NIOSH or European Standard EN 149 approved respirator
                      when necessary.

            **** SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES ****

Physical State:             Solid
Appearance:                 grey
Odor:                       none reported
pH:                         Not available.
Vapor Pressure:             Not available.
Vapor Density:              Not available.
Evaporation Rate:           Not available.
Viscosity:                  Not available.
Boiling Point:              Not available.
Freezing/Melting Point:     Not available.
Decomposition Temperature:
Solubility in water:
Specific Gravity/Density:
Molecular Formula:          C5H5N
Molecular Weight:           79.0417

                **** SECTION 10 - STABILITY AND REACTIVITY ****

    Chemical Stability:
         Stable under normal temperatures and pressures.
    Conditions to Avoid:
         Strong oxidants.
    Incompatibilities with Other Materials:
         None reported, however, may be incompatible with strong oxidizers.
    Hazardous Decomposition Products:
         Carbon monoxide, carbon dioxide.
    Hazardous Polymerization: Has not been reported

               **** SECTION 11 - TOXICOLOGICAL INFORMATION ****

    RTECS#:
         CAS# 1332-09-8 unlisted.
    LD50/LC50:
         Not available.
    Carcinogenicity:
      Pumice -
         Not listed by ACGIH, IARC, NIOSH, NTP, or OSHA.

                 **** SECTION 12 - ECOLOGICAL INFORMATION ****



                **** SECTION 13 - DISPOSAL CONSIDERATIONS ****

Chemical waste generators must determine whether a discarded chemical
is classified as a hazardous waste.
US EPA guidelines for the classification determination are listed in
40 CFR Parts 261.3. Additionally, waste generators must consult state
and local hazardous waste regulations to ensure complete and accurate
classification.
RCRA P-Series: None listed.
RCRA U-Series: None listed.

                 **** SECTION 14 - TRANSPORT INFORMATION ****

    US DOT
         No information available
    Canadian TDG
         No information available.

                 **** SECTION 15 - REGULATORY INFORMATION ****

US FEDERAL
    TSCA
         CAS# 1332-09-8 is listed on the TSCA inventory.
       Health & Safety Reporting List
         None of the chemicals are on the Health & Safety Reporting List.
       Chemical Test Rules
         None of the chemicals in this product are under a Chemical Test Rule.
       Section 12b
         None of the chemicals are listed under TSCA Section 12b.
       TSCA Significant New Use Rule
         None of the chemicals in this material have a SNUR under TSCA.
    SARA
       Section 302 (RQ)
         None of the chemicals in this material have an RQ.
       Section 302 (TPQ)
         None of the chemicals in this product have a TPQ.
       Section 313
         No chemicals are reportable under Section 313.
    Clean Air Act:
         This material does not contain any hazardous air pollutants.
         This material does not contain any Class 1 Ozone depletors.
         This material does not contain any Class 2 Ozone depletors.
    Clean Water Act:
         None of the chemicals in this product are listed as Hazardous
         Substances under the CWA.
         None of the chemicals in this product are listed as Priority
         Pollutants under the CWA.
         None of the chemicals in this product are listed as Toxic Pollutants
         under the CWA.
    OSHA:
         None of the chemicals in this product are considered highly hazardous
         by OSHA.
STATE
    Pumice is not present on state lists from CA, PA, MN, MA, FL, or NJ.
    California No Significant Risk Level:
    None of the chemicals in this product are listed.
European/International Regulations
    European Labeling in Accordance with EC Directives
         Hazard Symbols: Not available.
         Risk Phrases:
         Safety Phrases:
  WGK (Water Danger/Protection)
         CAS# 1332-09-8: No information available.
  United Kingdom Occupational Exposure Limits

  Canada
         CAS# 1332-09-8 is listed on Canada's DSL List.
         WHMIS: Not available.
         CAS# 1332-09-8 is not listed on Canada's Ingredient Disclosure List.
  Exposure Limits

                 **** SECTION 16 - ADDITIONAL INFORMATION ****

    MSDS Creation Date: 12/12/1997  Revision #2 Date:  8/02/2006

    The information above is believed to be accurate and represents the best
    information currently available to us. However, we make no warranty of
    merchantability or any other warranty, express or implied, with respect to
    such information, and we assume no liability resulting from its use. Users
    should make their own investigations to determine the suitability of the
    information for their particular purposes. In no way shall the company be
    liable for any claims, losses, or damages of any third party or for lost
    profits or any special, indirect, incidental, consequential or exemplary
    damages, howsoever arising, even if the company has been advised of
    the possibility of such damages.
--------------------------------------------------------------------------------


FisherFast Online - Web Based Order Entry